How to End A Troubleshooting Session

Final Procedure (this procedure must be done after any troubleshooting)

1. Remove the SCS service connector if it is connected.

NOTE: If the SCS service connector is connected and there are no DTCs stored in the PCM, the MIL will stay on when the ignition switch is turned ON (II).

2. Do the PCM Reset Procedure.
3. Turn the ignition switch OFF.
4. Disconnect the OBD II scan tool or Honda PGM Tester from the Data Link Connector.