Shift Control Solenoid Valves

The TCM controls transaxle shifting by delivering an output signal to shift control solenoid valves "A" and "B" on shift control solenoid valve assembly. Solenoid valves are operated in accordance with gear position. See SHIFT CONTROL SOLENOID VALVE OPERATION  table. Shift control solenoid valve assembly is located on transaxle. See Figure . Shift control solenoid valve "A" has a Blue/Yellow wire and solenoid valve "B" has a Green/White wire.

SHIFT CONTROL SOLENOID VALVE OPERATION

Shift Lever Position Solenoid Valve "A" Solenoid Valve "B"
"D" Or "D4" (1st Gear) Off On
"D" Or "D4" (2nd Gear) On On
"D" Or "D4" (3rd Gear) On Off
"D4" (4th) Off Off
"2" (2nd Gear) On On
"1" (1st Gear) On Off
"R" (Reverse) On Off