Valve Clearance: Vigor
- Engine temperature must be less than 100°F (38°C). Remove cylinder head cover. Align No. 1 mark on camshaft sprocket with mark on cam holder. See Fig 1
.
- Loosen adjustment screw lock nut, and adjust valves on cylinder No. 1. Tighten lock nut and recheck clearance. Repeat procedure if clearance changes.
- Rotate crankshaft 144 degrees. Align No. 2 mark on camshaft sprocket with mark on cam holder. See Fig 1
. Repeat adjustment procedure on cylinder No. 2. Tighten lock nut and recheck clearance. Repeat procedure on cylinders No. 4, 5 and 3.
VALVE CLEARANCE ADJUSTMENT
(VIGOR)
| Application |
In. (mm) |
| Intake |
.009-.011 (.24-.28) |
| Exhaust |
.011-.013 (.28-.32) |
Courtesy of AMERICAN HONDA MOTOR CO., INC.