LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2004 >> Verona L6-2.5L >> Repair and Diagnosis >> A L L Diagnostic Trouble Codes ( DTC ) >> Testing and Inspection >> P Code Charts >> P1863
April 5, 2026: LEMON Manuals is launched! Read the announcement.

P1863

DTC P1863 EDS 4 Output Open






Circuit Description
The pressure control valves (EDS valves 3, 4, 5 and 6) are precision electronic pressure regulators that control the operation of the clutches, brakes and lock-up clutch. The valve reduces the system pressure with which the downstream solenoid valves and electrical pressure regulating valves are supplied. It is possible to use smaller solenoid valves as a result. The EDS require a constant input pressure.

Conditions for Setting the DTC
^ Output ampere of the EDS 4 is less than 10 mA.
^ No DTC P1861, P1862.
^ Immediately after the above condition occurs.

Action Taken When the DTC Sets
^ The Malfunction Indicator Lamp (MIL) will illuminate.
^ The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
^ Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
^ After ignition OFF/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
^ Power supply cut off to the EDS valve.

Conditions for Clearing the MIL/DTC
^ The MIL will turn OFF when the malfunction has not occurred after three-ignition cycle.
^ A history DTC will clear after 40 consecutive warm up cycles without a fault.
^ Using a scan tool can clear history DTCs.

Diagnostic Aids
^ When DTC P1863 sets, the possible cause of fault could be EDS4 valve.

Steps 1-10:





DTC P1863 - EDS 4 Output Open