Overview - MECHATRONIC: Notes

Fig 1: Exploded View Of Mechatronic
GWWA34-11158Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
  1. Fluid Drain and Check Plug
    • 45 Nm
    • There is an overflow pipe with a 8 mm inner hex behind this bolt -item  ) OVERVIEW - MECHATRONIC - Overflow Pipe
    • Drain the transmission fluid via the drain- and check plug and removed overflow pipe.
  2. Seal
    • Always replace after removing
  3. Overflow Pipe
    • 3 Nm
    • Plastic
    • To drain the transmission fluid, remove the drain and check plug -item  ) OVERVIEW - MECHATRONIC - Fluid Drain and Check Plug and remove the overflow pipe.
    • The length of the overflow pipe determines the fluid level inside the transmission.
    • Allocation. Refer to the Parts Information.
  4. Bolt
  5. Oil Pan
  6. Bolt
  7. Seal
    • Always replace after removing
  8. DSG Transmission Mechatronic -J743-
  9. Bleed Cap
    • Placed on bleed pipe
  10. Bleed Pipe
    • Always replace after removing
    • Pressed into transmission
  11. Transmission Oil Pump
  12. Transmission Oil Pump Cover
  13. Bolt
  14. Bolt
    • Always replace after removing
    • Different versions. For the correct allocation. Refer to the Vehicle Diagnostic Tester.
    • There are different bolts for the transmission fluid pump. Refer to. Refer to DIFFERENT OIL PUMP BOLTS 
    • Quantity: 4
  15. Seal
    • Always replace after removing