MULTIFUNCTION Transmission Range Switch F125: Removing
-- Move the selector lever into the "N" position.
-- Turn off the ignition.
with 6 Cylinder Engines
-- Remove the coolant expansion tank. Refer to Description and Operation .
-- Disconnect the battery ground cable. Refer to Removal and Installation .
Continuation for All
-- Squeeze the selector lever cable locking mechanism -3- and pull the selector lever cable out the bracket.
-- Remove the selector lever cable -1- from the selector shaft lever by hand.
-- Do not bend or kink the selector lever cable.
-- Disconnect the multifunction transmission range switch connector from the multifunction transmission range switch.
-- Remove the nut -1-.
-- Remove the spring washer -2- and the lever -3- from the selector shaft -4-.
-- Bend back the hooks on the lock washer -2- using a screwdriver.
-- Replace the lock washer if any hooks break off.
-- Remove the nut -1-.
-- Remove the bolts -5-.
-- Remove the multifunction switch -4- and washers -2 and 3- from the selector shaft -6-.