Emissions Control Module Tightening Sequence.
| Step | Bolt | Steps |
|---|---|---|
| I | Screw-type clamp -1- | Position above the sealing flange and install the bolt. |
| II | Bolt -2- | Install hand-tight and immediately loosen 90° |
| III | Screw-type clamp -1- | Tighten to 8 Nm |
| IV | Bolt -2- | Tighten to 20 Nm |
| V | Bolt -3- | Install and pull to engage. Do not tighten or turn the bolt. |
| VI | Bolts -4- | Install and pull to engage. Tighten the bolts to 20 Nm. |
| VII | Bolt -3- | Tighten to 20 Nm |
-- Remove the lifter (left-hand thread) -1- on the cylinder head using the :3247 in direction of -arrow- until stop, then tighten an additional 90°.