LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2012 >> Routan S >> Repair and Diagnosis >> External Pages >> Different car >> Section 675 (Engine Controls - Reference Values (Except Diesel & Hybrid)) >> Reference Value Parameter Identification (PID)/Measured Signal Chart
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Reference Value Parameter Identification (PID)/Measured Signal Chart

WARNING: This page does not describe the selected car, but rather 35 other vehicles, including the 2007 Mercury Mountaineer, 2007 Mercury Monterey, 2007 Mercury Montego, 2007 Mercury Milan, and 2007 Mercury Mariner. However, it is still accessible from the selected car via links, so may be relevant.

The following listing reflects PIDS and/or measured values which may reveal a possible concern within each system shown. Match the category number with the related PID/measured signal and go to the Typical Diagnostic Reference Values  Charts.

PID/MEASURED SIGNAL CHART

Category Number Related PIDS/Measured Signals
5-9-10-17 WAC/ACCR
5-9-10-17 ACCS
5-10-17 ACP
5-10-17 ACP V
5-21 AIR
5-21 AIRF
5-21 AIRM
1-23 APP1
1-23 APP2
1-23 APP3
23 BPP (BOO)
18-19 CHT
18-19 CHT V
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CMP
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CKP
1-2-3-5-6-7-11-12-13-14-15-16-17-20-21 CMP1/2
10 CPP/PNP
3-5-6-7-9-11-15-16-20-21 DPFEGR
4-18-19-21-22 ECT (1)
4-18-19-21-22 ECT V
3-5-6-7-9-11-15-16-20-21 EGRMC1-4
3-5-6-7-9-11-15-16-20-21 EGRMDSD
3-5-6-7-9-11-15-16-20-21 EGRVR
5-18-19-20-21 EOT
5-18-19-20-21 EOT V
22 EPC/EPC1/EPC2/EPC3
22 EPC V
3-5-6-11-21 EVAPC V
3-5-6-11-21 EVAPPDC
3-5-6-11-21 EVMV
19 FCV 3
20 FLI (H)
20 FLI V
1 thru 21 FP
1 thru 21 FPM or FP M
1 thru 21 FRP
1 thru 21 FRP V
1 thru 21 FRT
5 FTP
1 thru 21 FUELPW1/2
1 thru 21 FUELSYS (OL/CLSD-LP)(1)
22-23 GEAR
5 GENFDC/GENRC
5 GFS/GENLI
19 HFC (FC3)
1 thru 21 HTR11/12/13/21/22
1 thru 21 IAC
2-3-5-7-8-10-22 IAT(1)
2-3-5-7-8-10-22 IAT2(1)
2-3-5-7-8-10-22 IAT V(1)
2-3-5-7-8-10-22 IAT2 V(1)
5-14-15-16-17-20 IMRC
5-14-15-16-17-20 IMRCM
5-14-15-16-17-20 IMTV
6-11-12-14 thru 18-20-21 INJ x F
4-5-16-18-19-20-21 KNOCK 1(1)
4-5-16-18-19-20-21 KNOCK 2(1)
19 LFC (FCI)
1 thru 21 LONGFT1/2(1)
1 thru 23 MAF(1)
1 thru 23 MAF V
1 thru 23 MAP V
1 thru 22 MISF
1 thru 21 HO2S11/12/13/21/22
22 OSS
10 PSP
10 PSPT
10 PSP V
5 PTO
1 thru 23 RPM(1)
5-14-16-17 SCBC
5-14-16-17 SCIPC
1 thru 21 SHRTFT1/2/11/12/21/22
15-16-18-19-20-21 SPRKADV(1)
22-23 SS1(SSA)/SS2(SSB)/SS3(SSC)/SS4(SSD)
1-23 TACM (-)
1-23 TACM (+)
6-14-16-20 TCC
22 TCIL
22-23 TCS
22-23 TFT
1-23 TP
1-23 TP1 NS
1-23 TP2 PS
1-23 TP V
22-23 TR
22-23 TR 1-4
22-23 TR V
22-23 TR D
22-23 TSS
2-4-5-9-10-11-16-17-18-19-20-21 VCT
2-4-5-9-10-11-16-17-18-19-20-21 VCTDC1/2
1-2-3-5-6-11-12-13-14 VPWR
22-23 VSS
(1) Generic PID

Some signals can only be measured and require the use of a digital multimeter (DMM).