Climatic Heating And A/C System Controls Multi-Pin Harness Connector
Special tools and workshop equipment required
- Test Box -V.A.G 1598/42-
- Adapter Cable -V.A.G 1598/47-
- Template -V.A.G 1598/47-2-
20-pin Harness Connector, T20b
3 - Center Outlet Temperature Sensor -G191-
5 - High Pressure Sensor -G65-
7 - CAN bus low
8 - CAN bus high
12 - Right seat heater (optional)
13 - Left seat heater (optional)
15 - Terminal 75 seat heater (optional)
16 - A/C Compressor Regulator Valve -N280-
18 - Center Outlet Temperature Sensor -G191-
19 - Terminal 30A
20 - Terminal 31
16-pin Harness Connector, T16j
1 - Temperature Regulator Door Motor -V68-, warm
2 - Evaporator Temperature Sensor -G308-
3 - Air distribution flap motor position sensor -G645-
4 - Footwell Outlet Temperature Sensor -G192-
5 - Temperature Regulator Door Motor Position Sensor -G92-
7 - + 5V for Temperature Regulator Flap Motor Position Sensor -G92- and Air Distribution Flap Motor Position Sensor -G645-
8 - Ground for the Footwell Vent Temperature Sensor -G192-, Front Air Distribution Door Motor Position Sensor -G92-, Evaporator Temperature Sensor -G308- and Air Distribution Door Motor Position Sensor -G645-
9 - Fresh/Recirculating Air Door Motor -V154-, open
10 - Fresh/Recirculating Air Door Motor -V154-, closed
11 - Temperature Regulator Door Motor -V68-, cold
12 - Air distribution flap motor -V428-, open
13 - Air distribution flap motor -V428-, closed
5-pin Harness Connector T5r
1 - 3rd blower speed
2 - 2nd blower speed
3 - 1st Blower speed
4 - 4th blower speed
5 - Terminal X