Fuel Metering Valve 2, Checking
Special tools and workshop equipment required
- Multimeter.
- Wiring diagram.
Test requirements
- The Fuel Pump (FP) Control Module -J538- OK.
- The Engine Component Power Supply Relay -J757- OK.
- The fuel filter OK.
- The parking brake engaged.
- The battery voltage at least 12.5 V.
- The selector lever of automatic transmission in position "P" or "N".
- All electrical consumers switched off (radiator fan must NOT run during test).
- A/C switched off.
- The fuel tank at least 1 /4 filled.
- The ignition switched off.
Test procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK .
Start diagnosis
-- Disconnect the Fuel Metering Valve 2 -N402- electrical harness connector -arrow-.
Checking internal resistance
-- Using a Multimeter --, check the Fuel Metering Valve 2 -N402- terminals for resistance
Specified value: 450 to 1000 Ω.
If the specified value was not obtained:
-- Replace the Fuel Metering Valve -N290-.
If the specified value was obtained:
Checking voltage
Switch the ignition on.
-- Using a Multimeter --, check the Fuel Metering Valve 2 -N402- electrical harness connector terminal 1 to Ground (GND) for voltage.
-- Switch the ignition off.
Specified value: battery voltage.
If the specified value was not obtained:
-- Check the wiring from the Fuel Metering Valve 2 -N402- electrical harness connector terminal 1 to the Engine Component Power Supply Relay -J757- terminal 2/87 for a short circuit to Ground (GND), or an open circuit.
-- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
-- If necessary, repair the wiring connection.
If no malfunctions are found in the wiring:
Checking wiring connections
If the manufacturers test box is being used. Perform the following step.
-- Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-- Remove the Motronic Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE, REPLACING .
-- Using a multimeter --, check the Fuel Metering Valve 2 -N402- electrical harness connector terminal 2 to the Engine Control Module (ECM) -J623- electrical harness connector T60 terminal 35 for an open circuit.
| Fuel Metering Valve 2 -N402- electrical harness connector terminal | Engine Control Module (ECM) -J623- electrical connector T60 terminal or test box socket |
|---|---|
| 2 | 35 |
Specified value: 1.5 Ω Max.
If the specification was not obtained:
-- Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).
-- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
-- If necessary, repair the faulty wiring connection.
If no malfunction is detected in the wiring:
-- Erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
-- Perform a road test to verify repair.
If the DTC does not return:
Repair complete, Generate readiness code. Refer to READINESS CODE .
-- End diagnosis.
If the DTC does return and no malfunction is detected in the wiring and the voltage supply was OK:
-- Replace the Motronic Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE, REPLACING .
-- Assembly is performed in the reverse of the removal.
Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
- Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
- If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
- If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .