Additional emission regulations
| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illumination |
|---|---|---|---|---|---|---|
| P2400 | Evaporative Emission System Leak Detection Pump Control Circuit/Open | -- Check Leak Detection Pump (LDP) -V144-.LEAK DETECTION PUMP V144, CHECKING -- Check Evaporative Emission (EVAP) Canister System for proper seal EVAP SYSTEM, CHECKING FOR LEAKS . |
Signal voltage 2.35-3.01 V |
|
0.5 Seconds |
|
| P2401 | Evaporative Emission System Leak Detection Pump Control Circuit Low | -- Check Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP V144, CHECKING -- Check Evaporative Emission (EVAP) Canister System for proper seal. Refer to EVAP SYSTEM, CHECKING FOR LEAKS . |
Signal voltage <3.0 V |
|
0.5 Seconds |
|
| P2402 | Evaporative Emission System Leak Detection Pump Control Circuit High | -- Check Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP V144, CHECKING -- Check Evaporative Emission (EVAP) Canister System for proper seal EVAP SYSTEM, CHECKING FOR LEAKS . |
Signal current > 3.0 A |
|
0.5 Seconds |
|
| P2403 | Evaporative Emission System Leak Detection Pump Sense Circuit/Open | -- Check Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP V144, CHECKING -- Check Evaporative Emission (EVAP) Canister System for proper seal. Refer to EVAP SYSTEM, CHECKING FOR LEAKS . |
Low signal voltage > 0.5 Sec. |
|
0.5 Seconds |
|
| P2404 | Evaporative Emission System Leak Detection Pump Sense Range/Performance | -- Check Leak Detection Pump (LDP) -V144-. Refer to LEAK DETECTION PUMP V144, CHECKING
. -- Check Evaporative Emission (EVAP) Canister System for proper seal. Refer to EVAP SYSTEM, CHECKING FOR LEAKS . |
High signal voltage > 12 V And Number of checks 30 |
|
0.5 Seconds |
|
| P2414 | O2 Sensor Exhaust Sample Error Bank 1, Sensor 1 | -- Check the oxygen sensors -- before catalytic converter. Refer to HEATED OXYGEN SENSORS G39 AND G108, CHECKING | Threshold 1:
|
|
11 Seconds |
|
| P2415 | O2 Sensor Exhaust Sample Error Bank 2 Sensor 1 | -- Check the oxygen sensors before catalytic converter. Refer to HEATED OXYGEN SENSORS G39 AND G108, CHECKING | Threshold 1:
|
|
11 Seconds |
|
| P2600 | Coolant Pump Control Circuit/Open | -- Check the Coolant Pump -V51-. Refer to COOLANT PUMP V51, CHECKING . | Signal voltage 4.5-5.5 V | - | 0.5 Seconds |
|
| P2602 | Coolant Pump Control Circuit Low | -- Check the Coolant Pump -V51-. Refer to COOLANT PUMP V51, CHECKING . | Signal voltage <3.0 V | - | 0.5 Seconds |
|
| P2603 | Coolant Pump Control Circuit High | -- Check the Coolant Pump -V51-. Refer to COOLANT PUMP V51, CHECKING . | Signal current, 0.6-1.2 A | - | 0.5 Seconds |
|
| P2626 | O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1 | -- Check the oxygen sensors before catalytic converter. Refer to HEATED OXYGEN SENSORS G39 AND G108, CHECKING | O2S signal front > 4.81 V |
|
3 Seconds |
|
| P2629 | O2 Sensor Pumping Current Trim Circuit/Open Bank 2 Sensor 1 | -- Check oxygen sensorsbefore catalytic converter. | O2S signal front > 4.81 V |
|
3 Seconds |
|