Flushing Circuit With E-Compressor
If an E-compressor is being replaced that does not have a mechanical fault (for example, a faulty circuit board), then determine how much refrigerant is in it.
Quantity: for example 50 cm 3
A new E-compressor is filled with 150 cm 3 refrigerant oil.
-- Pour 90 cm 3 out of the new E-compressor. 10 cm 3 is extra.
The E-compressor must be flushed to get all the refrigerant oil out.
The main wiring diagram shows the refrigerant circuit with E-compressor.
- A/C service station NOTE:
Flushing the E-compressor is performed manually.
-- Extract the refrigerant, if necessary.
-- Empty the Service Station old oil container.
NOTE:On some Service Stations, the oil is first separated in the vacuum phase and then it goes into the old oil container.
-- Set the amount of refrigerant on the Service Station to 2 kg and the oil quantity to 0.
-- Set up the Refrigerant circuit flushing device -VAS 6336/1- or Refrigerant circuit flushing device -VAS 6337/1A- between the service station and refrigerant circuit return line.
-- Evacuate the refrigerant circuit for 10 minutes. Then observe the vacuum display. If the vacuum remains constant, then fill the circuit with 2 kg refrigerant R134a. Then extract again and repeat the procedure one more time.
- Refrigerant Hose Of A/C Service Station
- From low pressure side of A/C service station (mostly colored blue) to output of refrigerant circuit flushing device.
- Refrigerant Circuit Flushing Device
- Different versions and different construction, for example, Refrigerant circuit flushing device -VAS 6336/1- or Refrigerant circuit flushing device -VAS 6337/1-.
- With filter, viewing glass, security valve, heater, refrigerant container, etc. (depending on version).
- Depending on the construction of the A/C service station and of refrigerant circuit flushing device, a check-valve may be installed at output of refrigerant circuit flushing device (to guarantee correct direction of refrigerant flow during flushing).
- Charge Hose For Refrigerant Circuit Flushing Device
- From connection to high pressure side of A/C compressor on refrigerant circuit (smaller diameter) to input of Refrigerant Circuit Flushing Device -VAS 6336/1- or Refrigerant Circuit Flushing Device -VAS 6337/1-.
- Adapter To Connection For High Pressure Side On Refrigerant Circuit
- From VW/Audi passenger vehicle set adapter chest -VAS 6338/1- adapter number -6338/3-.
- Refrigerant Line, High Pressure Side, From The E-Compressor
-- Remove the centering pin.
- E-compressor
- Refrigerant Line, Low Pressure Side, To The E-Compressor
-- Remove the centering pin.
- Adapter To Connection For Low Pressure Side On Refrigerant Circuit
- From VW/Audi passenger vehicle set adapter chest -VAS 6338/1- adapter number -6338/6-.
- Refrigerant Hose Of A/C Service Station
- From the high pressure side of the service station (mostly red) to the connection on the low pressure line above the engine to the E-compressor