Work sequence
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2002 Volkswagen Jetta, 2002 Volkswagen GTI, 2001 Volkswagen Jetta, 2001 Volkswagen GTI, and 2000 Volkswagen Jetta. However, it is still accessible from the selected car via links, so may be relevant.
- Connect Scan Tool (ST) VAG 1551 or mobile scan tool VAG 1552. Start engine and press buttons - 0 - and - 1 - to select "Engine Electronics" address word 01 (engine must be running at idling speed) → Scan Tool (ST) VAG 1551 , connecting and selecting functions .
Indicated on display
| Rapid data transfer HELP Select function XX |
- Press buttons - 0 - and - 8 - to select "Read Measuring Value Block" function 08, and press - Q - button to confirm input.
Indicated on display
| Read Measuring Value Block Input display group number XXX |
- Press buttons - 0 - , - 1 - and - 4 - to input display group number 14 - 014 - and press - Q - button to confirm input.
Indicated on display: (1-4 = display fields)
| Read Measuring Value Block 14 -> 1 2 3 4 |
- Check total number of misfires in display field 3.
- Check misfire recognition status in display field 4.
| Display fields | ||||
| 1 | 2 | 3 | 4 | |
| Display group 014: Ignition, misfire recognition | ||||
| Display | xxxx RPM | xxx % | xxx | Activated Blocked |
| Indicated | Engine speed (in 40 steps) | Engine load | Three Way Catalytic Converter (TWC) damaging misfires (total) | Misfire recognition status |
| Working range | 0-6800 RPM | 0-100 % | 0-65000 | --- |
| Specified value | 680-720 RPM | greater than 14% | 0 | activated |
| --- | --- | If the specified value is not obtained Evaluating display group 14, | ||
If the specifications are obtained:
- Press → button.
- Press buttons - 0 - and - 6 - to select "End Output" function 06 and press - Q - button to confirm input.
- Switch ignition off.
If the specified values are not attained:
- Change to display group 15 as follows:
- Press button - 3 - (VAG1551) or button ↑ (VAG1552).
Indicated on display: (1-4 = display fields)
| Read Measuring Value Block 15 -> 1 2 3 4 |
- Check misfiring in display fields 1-3.
- Check misfire recognition status in display field 4.
| Display fields | ||||
| 1 | 2 | 3 | 4 | |
| Display group 015: Ignition, misfire recognition | ||||
| Display | xxx | xxx | xxx | Activated Blocked |
| Indicated | Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 1 | Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 2 | Three Way Catalytic Converter (TWC) damaging misfires, Cyl. 3 | Misfire recognition status |
| Working range | 0-65000 | 0-65000 | 0-65000 | --- |
| Specified value | 0 | 0 | 0 | activated |
| If the specification is not obtained , Evaluating display groups 15 and 16 | ||||
If the specifications are obtained:
- Change to display group 16 as follows:
- Press button - 3 - (VAG1551) or button ↑ (VAG1552).
Indicated on display: (1 and 4 = display fields)
| Read Measuring Value Block 16 -> 1 4 |
- Check misfiring in display field 1.
- Check misfire recognition status in display field 4.
| Display fields | ||||
| 1 | 2 | 3 | 4 | |
| Display group 016: Misfiring recognition | ||||
| Display | xxx | xxx | xxx | Active Blocked |
| Indicated | Exhaust damaging misfires Cyl. 4 | Exhaust damaging misfires Cyl. 5 | Exhaust damaging misfires Cyl. 6 | Misfire status recognition |
| Working range | 0-65000 | 0-65000 | 0-65000 | --- |
| Specified value | 0 | 0 | 0 | activated |
| If the specification is not obtained , Evaluating display groups 15 and 16 | ||||
- Press → button.
- Press buttons - 0 - and - 6 - to select "End Output" function 06 and press - Q - button to confirm input.
- Switch ignition off.