Home >> Volkswagen >> 2003 >> New Beetle GLX, 2D Hatchback, Automatic >> Repair and Diagnosis >> Transmission >> Transmission Control Systems >> Controls, Housing - Automatic Transmission 01M (Hatchback) >> 37 Automatic Transmission - Controls, Housing >> Diagnosis And Testing >> Main Pressure, Checking >> Causes For Deviations From Specified Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Causes For Deviations From Specified Values

Possible causes Remedy
Idling speed too high Adjust engine
ATF pump faulty Check ATF pump and replace if necessary
Sticking valves in valve body Replace valve body

-- Switch engine off.

Solenoid valve connector

Fig 1: Identifying Fuse & Solenoid Valve Connector
GWWN37-0062Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Press fuse together and pull off connector.

-- Start engine.



Possible causes Remedy
ATF pump faulty Check ATF pump and replace if necessary
Sticking valves in valve body Replace valve body

After test:

-- Disconnect pressure tester VAG1702.

-- Install new bolt for main pressure port and tighten to 15 Nm.

-- Install solenoid valve connector.

-- Once connector has been fitted, check and erase DTC memory.

-- If necessary, install sound insulation.