Vehicles with engine code AFP
Vehicles with engine code BDF. See VEHICLES WITH ENGINE CODE BDF .
NOTE:
Do not use pressurized air for the following test!
- Remove front noise insulation.
- Disconnect vacuum hose from combination valve at Secondary Air Injection (AIR) Solenoid Valve -N112-. See item 5.
- Connect hand vacuum pump (VAG1390) at vacuum connection to combination valve.
- Remove intake hose to combination valve at air filter upper part (arrow) and blow into it with light pressure.
Combination valve must close.
NOTE:
To disengage, compress the buttons at the hose coupling.
- Operate vacuum pump.
Combination valve must open.
If the combination valve does not open or it is constantly open:
- Replace combination valve. See item 1.