Home >> Volkswagen >> 2000 >> New Beetle (1C1) L4-1.8L Turbo (APH) >> Repair and Diagnosis >> Accessories and Optional Equipment >> Antitheft and Alarm Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Scan Tool Testing >> Measuring Value Blocks (Function 08) >> Reading Measuring Value Blocks
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Reading Measuring Value Blocks




Read Measuring Value Block (function 08)

Use this function to determine immobilizer system status.
- Connect VAG 1551 Scan Tool (ST), input address word 17, "Instrument cluster", and press -> button until "Select function XX" appears in display. Scan Tool Connecting and Initial Checks

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -8- to select function 08," Read measuring value block".

Indicated on display


Rapid data transfer Q
08 - Read Measuring Value Block



- Press -Q- button to confirm input.

Indicated on display


Read Measuring Value Block
Input display group number XX



- Press button -0- once and -2- twice to enter display group 22.
- Press -Q- button to confirm input.
- Indicated on display (example only)


Read Measuring Value Block ->
1 1 1 2



NOTE:
- Interpreting measured values in individual display fields.
- When printer is switched on, the actual display is printed out.
- Press -> button if measured value specifications are met in all display fields.