LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 1995 >> EuroVan Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 19 (Diagnosis) >> Read Measuring Value Block (Function 08) >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Read Measuring Value Block (Function 08): Notes

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2003 Volkswagen EuroVan, 2002 Volkswagen EuroVan, 2001 Volkswagen EuroVan, 2000 Volkswagen EuroVan, and 1999 Volkswagen EuroVan. However, it is still accessible from the selected car via links, so may be relevant.

Connect scan tool V.A.G 1551 and enter address word "02 Transmission electronics" and advance until "Select function XX" indicated on display. See SCAN TOOL V.A.G 1551, CONNECTING AND SELECTING FUNCTIONS  under ON BOARD DIAGNOSTIC (OBD), INITIATING.

Indicated on display:

Press keys 0 and 8. (The function "Read measuring value block" is selected with 08.)

Indicated on display:

Confirm entry with key Q.

Indicated on display:

Enter display group number. See LIST OF SELECTABLE DISPLAY GROUP NUMBERS  .

Confirm entry with key Q.

There are always 4 display zones in the measuring value block (if necessary in physical quantities):

For decoding the individual values in display zones 1 to 4, see TEST TABLE  .

If the printer is switched on, the current display is printed out on the log. If the specified values are obtained in all the display zones, press right arrow key.

Indicated on display: